Product | Product Name | Specification |
---|---|---|
11 KV Single Phase Epoxy Cast PT | Ratio :- 11000/110 volts Accuracy class :- 0.1, 0.2 and 0.5 (For Metering) / 3P and 5P ( For Protection) Rated Output :- 10/15/25/50/100 VA Application :- Metering / Protection Voltage Factor :- 1.2 for Continuous to 1.9 for 30 Sec . Insulation Level :- 28 KV (Induced voltage ) as one end Earthed , 75KV (P) Impulse Level. Dimensions :- 305mm x 150 mm x 225mm +/- 5 % overall tolerance |
|
11 KV Three Phase Epoxy Cast PT | Ratio:- 11000 / 110 volts Accuracy class :- 0.1, 0.2 and 0.5 (For Metering) / 3P and 5P ( For Protection) Rated Output :- 10/15/25/50/100 VA Application :- Metering / Protection With and Without in built Primary Fuse . Voltage Factor :- 1.2 for Continuous to 1.9 for 30 Sec . Insulation Level :- 28 KV separate source and Induced over voltage ,75KV (P) impulse level. Dimensions :- 450mm x 215 mm x 310 mm +/- 5 % overall tolerance |
|
11 KV Single Phase Oil Cooled PT | Ratio :- 11000/110 volts Accuracy class :- 0.1, 0.2 and 0.5 (For Metering) / 3P and 5P ( For Protection) Rated Output :- 10/15/25/50/100 VA Application :- Metering / Protection Voltage Factor :- 1.2 for Continuous to 1.9 for 30 Sec . Insulation Level :- 28 KV (Induced voltage ) as one end Earthed ,75KV (P) Impulse Level . Dimensions :- 310mm x 430 mm x 670 mm Height +/- 5 % overall tolerance . |
|
11 KV Three Phase Oil Cooled PT | Type:- Indoor / Outdoor Ratio :- 11000 / 110 volts Accuracy class:- 0.1, 0.2 and 0.5 (For Metering) / 3P and 5P ( For Protection) Rated Output :- 10/15/25/50/100 VA Application :- Metering / Protection Voltage Factor :- 1.2 for Continuous to 1.9 for 30 Sec . Insulation Level :- 28 KV separate source and Induced over voltage ,75KV (P) Impulse Level. Dimensions :- 530mm x 300 mm x 375 mm +/- 5 % overall tolerance . |
|
DRAW OUT TYPE PT | Type:- Indoor / Outdoor Ratio :- 11000 / 110 volts Accuracy class:- 0.1, 0.2 and 0.5 (For Metering) / 3P and 5P ( For Protection) Rated Output :- 10/15/25/50/100 VA Application :- Metering / Protection Voltage Factor :- 1.2 for Continuous to 1.9 for 30 Sec . Insulation Level :- 28 KV separate source and Induced over voltage ,75KV (P) Impulse Level. Dimensions :- 1100mm x 550 mm x 470 mm +/- 5 % overall tolerance . |
33 KV Single Phase Epoxy Cast PT | Ratio :- 33000 / 110 volts Accuracy class:- 0.1, 0.2 and 0.5 (For Metering) / 3P and 5P ( For Protection) Rated Output :- 10/15/25/ VA Application :- Metering / Protection Voltage Factor :- 1.2 for Continuous to 1.9 for 30 Sec . Insulation Level :- 70 KV (Induced voltage ) as one end Earthed , 170KV (P) Impulse Level. Dimensions :- 305mm x 150 mm x 225 mm +/- 5 % overall tolerance . |
|
33 KV Single Phase Oil Cooled PT | Ratio :- 33000 / 110 volts Accuracy class:- 0.1, 0.2 and 0.5 (For Metering) / 3P and 5P ( For Protection) Rated Output :- 10/15/25 VA Application :- Metering / Protection . Voltage Factor :- 1.2 for Continuous to 1.9 for 30 Sec . Insulation Level :- 70KV (Induced voltage ) as one end Earthed , 170KV (P) Impulse Level. Dimensions :- 425mm x 325 mm x 1000 mm Height +/- 10 % overall tolerance . |