Product | Product Name | Specification |
---|---|---|
11 KV Epoxy Cast CT (Indoor) | Ratio :- Single/ Double/ Triple Ratio. Rated Primary current :- 5Amps to 2000Amp Rated Secondary current :- 1A or 5Amp or 0.577Amp. Accuracy class:- 0.1 ,0.2 , 0.2S , 0.5 , 0.5S, 1.0 , 3.0 (for Metering) 5P,10P,15P and ALF from 5 to 20 (for Protection) Rated Output: 2.5, 5, 7.5, 10, 15, 20, 30VA Application:- Metering or Protection Insulation Level :- 28 KV / 75KV (P) ( impulse level) Dimensions: Single Core CT :-300mmx150mmX250mm+/- 10 % tolerance Double Core CT:-360mmx150mmX260mm+/- 10 % overall tolerance Triple Core CT:-380mmx150mmX260mm+/- 10 % overall tolerance |
|
DEAD TANK DESIGN LIVE TANK DESIGN |
11 KV Oil Cooled CT (Outdoor) Available in Live tank and Dead Tank Design. |
Ratio :- Single/ Double/ Triple Ratio. Rated Primary current :- 5Amps to 2000Amp Rated Secondary current :- 1A or 5Amp or 0.577Amp. Accuracy class:- 0.1 ,0.2 , 0.2S , 0.5 , 0.5S, 1.0 , 3.0 (for Metering) 5P,10P,15P and ALF from 5 to 20 (for Protection) Rated Output: 2.5, 5, 7.5, 10, 15, 20, 30VA Application:- Substation Metering or Protection Insulation Level :- 28 KV / 75KV (P) ( impulse level) Dimensions: Live Tank:- 500mmx325mmX850mm+/- 10 % tolerance Dead Tank (Two Bushing Type ) :- 400mmx400mmX650mm(ht.) +/- 10 % overall tolerance |
Product | Product Name | Specification |
---|---|---|
33 KV Epoxy Cast CT (Indoor) | Ratio :- Single/ Double/ Triple Ratio. Rated Primary current :- 5Amps to 2000Amp Rated Secondary current :- 1A or 5Amp or 0.577Amp. Accuracy class:- 0.1 ,0.2 , 0.2S , 0.5 , 0.5S, 1.0 , 3.0 (for Metering) 5P,10P,15P and ALF from 5 to 20 (for Protection) Rated Output:- 2.5, 5, 7.5, 10, 15, 20, 30VA Application:- Metering and Protection Insulation Level :- 70 KV / 170KV (P) ( impulse level) . Dimensions: Single Core CT :- 215mmX 175mmX 360mm+/- 10 % tolerance Double Core CT:- 310mmx250mmX350mm+/- 10 % overall tolerance Triple Core CT:- 380mmx250mmX360mm+/- 10 % overall tolerance |
|
DEAD TANK DESIGN LIVE TANK DESIGN |
33 KV Oil Cooled CT (Outdoor) Available in Live tank and Dead Tank Design. |
Ratio :- Single/ Double/ Triple Ratio. Rated Primary current :- 5Amps to 2000Amp Rated Secondary current :- 1A or 5Amp or 0.577Amp. Accuracy class:- 0.1 ,0.2 , 0.2S , 0.5 , 0.5S, 1.0 , 3.0 (for Metering) 5P,10P,15P and ALF from 5 to 20 (for Protection) Rated Output: 2.5, 5, 7.5, 10, 15, 20, 30VA Application:- Substation Metering and Protection Insulation Level :- 70 KV / 170KV (P) ( Impulse level) Dimensions: Live Tank:- 550mmx400mmX1100mm +/- 10 % overall tolerance Dead Tank (Two Bushing Type ) :- 450mmx450mmX900mm +/- 10 % overall tolerance |
Product | Product Name | Specification |
---|---|---|
Tape Insulated CT (Indoor) | Ratio :- Single / Dual ratio . Rated Primary current :- 30 A to 5000 A Rated Secondary current :- 1A , 5A, 0.577A. Accuracy class:- 0.2,0.2S,0.5, 0.5S 1.0 , 3.0 ,5.0 (for Metering) 5P,10P,15P and ALF from 5 to 20 (for Protection) Rated Output: 1.25, 2.5, 5, 7.5, 10, 15, 20, 25,30VA Application:- Indoor Metering and Protection Insulation Level :- 3 KV for 1.0 Min. Insulation Class :- B , E, F as per the requirement . |
|
Epoxy Cast CT (Indoor) |
Ratio :- Single / Dual ratio . Accuracy class:- 0.2,0.2S,0.5, 0.5S 1.0 , 3.0 ,5.0 (for Metering) |
|
Cycloelephatic Epoxy Cast CT (Outdoor) | Ratio :- Single / Dual ratio . Rated Primary current :- 100 Amp to 2000Amp. Rated Secondary current :- 1A , 5A . Accuracy class:- 0.2 0.5 , 0.5S or 1.0 . Rated Output: 5 , 10 VA . Application:- Outdoor energy metering . Insulation Level :- 3 KV Insulation Class :- B , E, F as per the requirement . |
|
Plastic Casing CT | Rated Primary current :- 100Amp to 1600Amp Rated Secondary current :- 1A , 5A, 0.577A.. Accuracy class:- 0.2,0.2S,0.5, 0.5S 1.0 , 3.0 ,5.0 (For Metering) 5P, 10P, 15P and ALF 5,10,15,20 ( for Protection ) Rated Output: 1.25 VA to 30 VA. Application:- Indoor for Metering / Switchgear Insulation Level :- 3 KV Insulation Class :- B |
|
Protection Relays CT | Rated Primary current :- 100 Amp to 630 Amp Rated Secondary current :- 1A , 5A Accuracy class:- 5P, 10P etc. Rated Output: 5 VA maximum Application:- Indoor for Protection Insulation Level :- 3 KV Insulation Class :- B , E, F as per the requirement |
|
Inter-posing and Summation CT |
Interposing Summation |
|
Core Balancing CT | Rated Primary current :- 50, 100, 150A Rated Secondary current :- 1A , 5A Accuracy class:- PS with specified Knee Point Voltage . Application:- Indoor Protection with Earth leakage Relay . Insulation Level :- 3 KV Insulation Class :- B , E, F as per the requirement . |
|
Switchgear CT | Ratio :- Single/ Double/ Triple Ratio. Rated Primary current :- 100 Amp to 1600 Amp Rated Secondary current :- 0.2 A , 0.5 A , 1A ,2.5A 5A. Accuracy class:- 5P , 10P , PS etc . Rated Output: 5 VA Max . Application:- Indoor Protection Insulation Level :- 3 KV Insulation Class :- B , E, F as per the requirement . |